Specs

Facility at a Glance

TRG Datacenters

Size
Size
150,000 Sq Ft
Remote Hands On
Remote Hands On
Free 24/7, with emergency availability with 15 mins response time
Hours of Operation
Hours of Operation
24/7
Reviews (on Google)
Reviews (on Google)
89 5-stars
SLA
SLA
100% uptime guarantee, with 100% of your month free for portion of services affected by ANY downtime. We've delivered 100% uptime since inception including during all maintenance operations and severe weather
Floodplain
Floodplain
Outside of the 500-year floodplain, and we then still built 3 feet above ground level
Hurricane Resistance
Hurricane Resistance
With a single sloped roof, with 2 layers of leak protection including a concrete deck. It’s rated for 185+ MPH, that makes the data center over-prepared by 145% compared to the max wind speed
Location
Location
Near both the I-45 and I-99 making it highly accessible by any part of Houston, and remains accessible during severe flooding.
Power
Power
Four different substations in the area supplying power, owned medium voltage infrastructure with spare parts. Dual power distribution buses, physically separated power & cooling paths. Critical Load designation from CentrePoint Energy ensures priority restoration in the event of any outage.
Batteries / UPS
Batteries / UPS
Pure lead batteries deployed in 2(N+1) reliability configuration, achieving published performance for ultra-fast discharge. Multiple redundant and fault tolerant compartmentalized units. We use Toshiba G9000s for category defining efficiency and achieving fault tolerance
Stock Parts
Stock Parts
On-site replacement parts for every system in case they are needed
Comparison
Comparison
-

Location
Location
Indoor, significantly more reliable than outdoor
Specification
Specification
Multiple 1.5 MVA Rolls Royce MTU V18 Twin Turbo Systems with hurricane resistant louver systems
Fuel supplies
Fuel supplies
Independent and isolated fuel reserves lasting 4+ days, and the option for natural gas bi-fuel extending runtime to 12+ days without re-fueling
Emergency Fuel
Emergency Fuel
Emergency backup contracts for infinite fuel resupply
Time to generator
Time to generator
Less than 10 seconds and meets NFPA 110 requirements

Water
Water
Our first two data halls are completely water-free, eliminating any risk of internal water distribution. The upcoming Phase Three expansion is designed to support direct-to-chip cooling while maintaining full Fault Tolerance
High Performance Computing
High Performance Computing
Fully modular, compartmentalized cooling enables 50kW cabinets and high-density GPU environments or more

Cross Connects
Cross Connects
Free, forever, always
Carriers
Carriers
16+ and free entry for any you want to bring
Redundant Infrastructure
Redundant Infrastructure
Truly redundant, compartmentalized and fault tolerant. Engineered so that the failure of any single entire subsystem (e.g. one entire power path) will not disrupt operations
Meet Me Rooms
Meet Me Rooms
Dual entries into dual meet me rooms
Cabling
Cabling
Milspec armored core fiber cabling with corning high bend radius glass for ultra reliability

Team history
Team history
FISMA compliant. Experience working with Department of Defense, MIT Lincoln Lab & the CIA
Fiver layers of security
Fiver layers of security
Customizable
Customizable
Fully customizable cabinet and suite security for example; motion sensors, man traps and armed security guards
Local area crime rate
Local area crime rate
#1 City to live in America in 2022

HIPAA
HIPAA
SSAE
SSAE
SOC
SOC
PCI
PCI
NFPA 110
NFPA 110

Offices
Offices
30+ over-sized offices (11×13 sq. ft) available for rent so you can build your own NOC
Conference Rooms
Conference Rooms
Multiple executive conference rooms
Breakout Rooms
Breakout Rooms
Showers
Showers
Wifi Throughout
Wifi Throughout

Whats the real cost?

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam.
Scott Mowry

Customer Stories

Scott @ Bishop Lifting Products

"The way TRG has implemented power and HVAC systems and associated resiliency is some of the best I’ve ever seen."

Have Questions?

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua inventore dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua inventore dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua inventore dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua inventore dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis.