In a world of high-performance computing, data centers, and electronics, cooling solutions have grown more critical than ever. As the density of processors and the intensity of computing tasks increase, so do the demands on thermal management.
A well-optimized cooling system effectively removes heat from critical components, allowing machines to operate efficiently and at stable temperatures. Alternative methods like liquid and immersion cooling provide robust ways to manage heat in various applications.
But what exactly is the difference between liquid cooling and immersion cooling? Why does it matter if data centers require lower energy consumption and excellent reliability? And how do factors like power usage, direct contact with fluid, or using water versus other cooling mediums impact performance?
Whether you are researching new cooling systems for a modern data center or want to broaden your understanding of cutting-edge cooling methods, this post will clarify the distinctions and help you identify the best fit for your needs.
What is Liquid Cooling?
Liquid cooling is a system that circulates a cooling fluid often water mixed with additives through a closed loop to absorb heat from high-temperature devices.
The fluid is typically pumped through cooling blocks that directly interact with the hot components, such as the CPU or GPU, transferring heat to the fluid.
This liquid then travels to a radiator or heat exchanger, where the heat is released into the surrounding air (or another medium), and the cooled fluid is recirculated.
Many people have experience with liquid cooling in gaming computers or high-performance workstations.
However, data centers also implement more complex versions of liquid cooling, known as direct-to-chip (D2C) cooling, where water or other specialized fluids directly contact cold plates attached to critical chips.
Key Advantages of Liquid Cooling
- Improved Thermal Efficiency: Water and specialized liquids have a higher specific heat capacity than air, meaning they can absorb more heat before experiencing a temperature rise. This allows more efficient heat transfer, enabling hardware to run at lower temperatures.
- Smaller Footprint: Because liquid cooling systems can handle higher heat loads with less real estate, they free up space in data centers.
- Reduced Noise: Since liquids can more efficiently remove heat, fewer fans may be required, resulting in quieter operation.
- Scalability: Liquid cooling can be scaled to handle large volumes of heat, making it suitable for modern data centers with racks of servers with high power demands.
Challenges of Liquid Cooling
- Maintenance Complexity: Liquid cooling loops involve pumps, pipes, cold plates, and coolant reservoirs. Each piece of hardware can fail, potentially leading to leaks or downtime.
- Initial Investment: The upfront cost for installing water-cooling systems can be higher than an equivalent air-cooled design.
- Fluid Management: If not properly sealed, fluid can become contaminated or evaporate over time. Fluid changes and checking for corrosion inhibitor levels can be routine requirements.
What is Immersion Cooling?
Immersion cooling is a more radical approach compared to traditional liquid cooling. Instead of piping fluid through specialized blocks, the entire server or electronic device is submerged (partially or fully) in a dielectric fluid that does not conduct electricity.
Common dielectric fluids include engineered oils or specialized liquids developed for electronics. Because they are non-conductive, immersing electronic components is safe; there is no risk of a short circuit.
In a single-phase immersion cooling system, the fluid remains in its liquid state, absorbing heat from the components and cycling it through a cooling loop or heat exchanger. In a two-phase immersion cooling system, the fluid changes from liquid to vapor when it absorbs enough heat.
The vapor then condenses into a liquid in a cooling condenser, cycling back into the main tank. This two-phase approach can be highly effective at managing heat loads efficiently.
Key Advantages of Immersion Cooling
- Superior Heat Transfer: By surrounding every surface of the device, immersion cooling provides direct, uniform contact with the fluid, removing heat more effectively than air or traditional liquid cooling systems.
- Component Reliability: Without fans blowing air (and dust) onto electronics, immersion cooling can reduce particulate contamination and vibration, potentially extending the lifespan of components.
- Reduced Maintenance: In single-phase immersion systems, the fluid is usually sealed in a tank, significantly lowering the risk of leaks. Fewer moving parts mean less mechanical wear and tear.
- Energy Efficiency: Immersion cooling often operates with lower overall power consumption, especially regarding the overhead required for temperature regulation. The typical data center approach, Power Usage Effectiveness (PUE) tends to be more favorable with immersion cooling because less energy is spent on air-based cooling infrastructure.
Challenges of Immersion Cooling
- Fluid Costs: Dielectric fluids can be significantly more expensive than water. If a system requires large volumes of fluid, costs can escalate quickly.
- Complexity of Retrofitting: Transitioning an existing data center to immersion cooling can be complex, given the need for specialized tanks and changes to power distribution. It often works best in new builds or with carefully planned retrofits.
- Equipment Handling: Submerging entire servers into fluid means operators need different procedures for installation, cable management, maintenance, and upgrades.
Liquid Cooling vs Immersion Cooling: Key Differences
To fully understand each system’s pros and cons, it’s crucial to examine how these two advanced cooling approaches compare, particularly in terms of performance, cost, and deployment complexity.
Efficiency and Heat Removal
Liquid Cooling
A well-designed liquid cooling loop can effectively remove large amounts of heat, but efficiency can vary based on pump quality, fluid selection, and the design of heat exchangers.
Liquid cooling typically outperforms air cooling but may not provide the same comprehensive coverage as immersion since only the cooled surfaces in direct contact with cold plates benefit significantly.
Immersion Cooling
Heat removal is uniform and efficient because the fluid surrounds every part of the hardware. Especially in two-phase systems, heat absorption and rejection can be near instantaneous.
This can translate into lower operating temperatures for all components, leading to higher stability and better performance.
Implementation Complexity
Liquid Cooling
Many IT professionals are familiar with this concept. Installing closed-loop systems for direct-to-chip cooling typically involves adding cold plates and fluid channels and ensuring no leaks.
While it’s not as straightforward as adding fans, the knowledge and skill set for water-based cooling are well-established in many technical communities.
Immersion Cooling
In a data center context, immersion cooling usually requires specialized tanks or baths to accommodate entire servers, plus the plumbing necessary to circulate the dielectric fluid to a heat exchanger.
This can mean a significant change in workflow and a steeper learning curve for employees.
Cost Considerations
Liquid Cooling
If you only need to cool a few high-power servers, the cost of liquid cooling is reasonable. However, in large-scale data centers, the infrastructure to circulate water or other coolants becomes more expensive.
Still, the fluid, often water or an inexpensive mixture, tends to be cheaper than dielectric fluids.
Immersion Cooling
While immersion cooling systems can reduce operational costs due to lower energy consumption and simplified hardware maintenance (fewer fans, less dust), the initial investment in tanks and dielectric fluids is typically higher.
The fluid must also be replaced or regenerated over a long product lifecycle, which can represent a substantial cost.
Maintenance and Operational Considerations
Liquid Cooling
Components like pumps, radiators, and tubing can fail or degrade over time. Regular inspections for leaks, corrosion, and fluid levels are necessary.
Some server sections remain air-cooled in direct-to-chip systems, requiring a hybrid approach for non-immersed parts.
Immersion Cooling
Once set up, immersion systems often have fewer moving parts. Maintenance mainly involves monitoring fluid quality, ensuring heat exchangers function correctly, and checking seals or gaskets.
However, physically handling a server submerged in fluid can be cumbersome and requires specialized training.
Scalability and Future Trends
Liquid Cooling
As components become more powerful and compact, direct liquid cooling will remain a viable method to manage heat. Integration with facility-wide chilling systems can improve efficiency, making it a popular choice for modular expansions in large data centers.
Immersion Cooling
Immersion cooling holds promise for next-generation, highly dense servers and specialized hardware (like ASICs for cryptocurrency mining or advanced AI applications). Its ability to handle skyrocketing thermal loads with minimal energy overhead is a compelling proposition.
Many see immersion cooling as a future-proof choice, especially in data centers requiring intense computing in a relatively small footprint.
What is Air Cooling in Data Centers?
Air cooling is an alternative form of cooling system, widely used in data centers all over the world. It works by pumping cooled air over hardware, to reduce their temperature and stop them from overheating.
Data centers typically use a centralised system for air cooling. Air conditioning is used to generate cold air, which is then pumped through the facility through what’s commonly known as “cold aisles”.
As equipment generates heat and heats up the surrounding air, that air is then taken through the “hot aisle,” which returns it to the air conditioning system where it can be cooled and used once again.
Often, liquid cooling systems are used in conjunction with air cooling systems. That’s because unlike immersion cooling, liquid cooling won’t remove 100% of generated heat. Air cooling is also important in maintaining air quality throughout data centers.
The advantages of air cooling
Air cooling is far from a new discovery. Data centers have been relying on systems like these for decades, so unlike newer options like liquid cooling this really is a tried and tested method. Let’s take a look at its advantages to see why air cooling fast became the go-to option for data centers all over the world.
Proven results: Air conditioning is an established way of cooling air, so air cooling systems are immediately familiar to all professionals working with them. Professionals are therefore comfortable using such systems and don’t require extensive, specialised training to do so.
Competition and availability: There are many manufacturers to choose from when selecting air conditioning systems, giving data centers plenty of options and good availability. Data centers can easily find professionals with the skills and knowledge to manage any required remains at a moment’s notice, providing great peace of mind.
Low risk of damage: Unlike liquid, which can devastate equipment in a matter of seconds, air isn’t immediately damaging. Cooling equipment using air is therefore seen as a safer method. It’s also simpler to modify the use of air cooling systems as and when required, allowing data center engineers to keep on top of rising and falling demand to maintain maximum efficiency.
The drawbacks of air cooling
Air cooling has its benefits, but there are also drawbacks to relying on air cooling entirely. As discussed, the huge amounts of heat now being generated by the likes of AI and HPC necessitate the use of more powerful cooling methods. But there are other challenges in air cooling to be aware of, too.
Efficiency: Air cooling isn’t as efficient as other cooling methods. Compare it to liquid cooling, and you can really see the difference in efficiency. Less energy is used to cool liquid than air, so liquid systems are more cost-effective and eco-friendly to run than more traditional air cooling options.
Cost: Poor efficiency means higher running costs, as more energy is needed to keep air cooling systems running. This means that businesses are faced with higher bills for the same service, and these costs can quickly escalate as demand for cooling increases.
Sustainability: Liquid cooling, as the more efficient option, is also more environmentally friendly. Data centers as a whole need to reduce the amount of energy they consume, and switching to liquid cooling is a simple way of doing so. Sustainability is now a key concern for many businesses and their customers, so this is fast becoming a sticking point for companies as they select their preferred cooling method.
Future-proofing: The amount of heat being generated by equipment is rising rapidly, and this is a trend that’s set to continue in the future. As such, many businesses are having to introduce different cooling methods to manage that heat. Air cooling systems have their limits, and in most cases they simply can’t cater for the huge amounts of heat being generated by HPC on their own. Companies looking to future-proof their setups are increasingly looking to liquid cooling options instead.
Why are businesses choosing liquid cooling over air cooling?
In an ever increasing number of data centers, liquid cooling is being used in conjunction with, or instead of, air cooling systems. There are many reasons why businesses are now opting for liquid cooling over air cooling. Here are some of the big ones.
Sustainability
Liquid cooling can dramatically reduce the carbon footprint of a data center, because it uses less energy to do the same job as air cooling. This means that less electricity is required, and the data center immediately becomes more sustainable.
Air cooling also uses huge amounts of water in evaporation, which also has a detrimental impact in terms of sustainability. With today’s customers ever more aware of the environmental impact of their purchasing decisions, this is becoming a key deciding factor for many companies.
Expense
Liquid cooling systems come with a higher upfront cost, but once they’re up and running they’re actually more cost-effective than air cooling options. This too is down to the amount of power needed to keep these systems up and running. Liquid cooling requires less energy, and therefore its running costs are lower.
Setup
Both air cooling and liquid cooling systems require quite complicated setup processes, so there’s no dramatic difference here. In fact, liquid cooling is often more complex to set up as traditional data centers aren’t designed for the plumbing and pipework needed. However, scalability is a real deciding factor for many companies.
Liquid cooling is far more scalable than air cooling, which means that while its initial setup can be complex and disruptive, once it’s in place it’s there for the future, so businesses benefit from peace of mind from that point on.
Geographical location
The location of some data centers mean that air cooling is even less reliable than it otherwise would be.
If a data center is located in a region with a warmer climate, it becomes harder to cool air taken from outside the facility, and therefore it’s more energy intensive. This isn’t such a problem for data centers in colder climates, but it’s something that needs to be considered when weighing up your options.
Scalability
We’ve talked about future-proofing, and this too is a key reason why so many companies are now opting for liquid cooling instead of air cooling. Air cooling is limited by the availability of power. There are also limits in terms of the level of demand that can be put on existing electrical circuits.
Liquid cooling doesn’t have the same limitations, which is why it’s a far better option for businesses managing growing demand. If scalability is a concern, liquid cooling is a more sensible choice.
Infrastructure performance
Rising heat can impact performance if existing air cooling systems aren’t equipped to cope with it. Companies prioritising fast and reliable performance are increasingly looking to liquid cooling, because it allows them to avoid placing such limits on the use of their equipment.
Maintenance
If there’s one area in which air cooling still comes out on top, it’s maintenance. Air cooling systems have been around far longer, so it’s still much easier to repair and maintain these systems than newer liquid cooling systems.
Issues relating to liquid cooling usually require the assistance of skilled maintenance professionals, which means that keeping these systems in working order can be more costly in terms of both time and money.
Real-World Applications
From high-performance computing clusters to cryptocurrency mining setups, real-world use cases highlight how liquid and immersion cooling excel in specific scenarios, demonstrating their versatility and value across various industries.
High-Performance Computing (HPC) and AI
Liquid and immersion cooling are widely used in high-performance computing clusters that handle AI training, simulations, and complex data analytics.
These systems often feature large arrays of GPUs or specialized chips with substantial power demands. By moving away from air-based solutions, HPC operators can achieve lower operating temperatures and more consistent performance.
Cryptocurrency Mining
Heat dissipation is a key concern in cryptocurrency mining operations. High-power ASIC miners produce massive amounts of heat. Immersion cooling, especially in a two-phase setup, can help sustain peak performance without the risk of overheating.
Some miners find that the fluid environment prolongs the life of their hardware by reducing thermal stress.
Edge Computing
With the rise of the Internet of Things (IoT) and edge computing, smaller yet powerful server racks are now being installed in locations other than traditional data centers.
These remote or less controlled environments might face extreme temperatures or dust. Immersion cooling can be a robust solution, though direct liquid cooling could be easier to implement depending on the local water infrastructure.
Cloud Service Providers
Major service providers operate vast cloud data centers, known as centers of data processing, that are under constant pressure to optimize power usage and ensure reliable uptime.
Both immersion and liquid cooling solutions offer ways to improve Power Usage Effectiveness (PUE) and manage large-scale deployments of racks filled with powerful CPUs and GPUs.
Energy and Environmental Considerations
With sustainability at the forefront of modern data center design, liquid and immersion cooling offers significant benefits for power consumption, heat reuse, and overall environmental impact.
Power Consumption
One of the main goals of advanced cooling techniques is to reduce overall power consumption. Traditional data centers rely on large fan arrays and air conditioners to keep ambient temperature within safe limits, which can be highly energy-intensive.
Liquid and immersion cooling lowers the required overhead by transferring heat from the electronics more efficiently.
Liquid Cooling
Pumps and heat exchangers require power, which can be substantially less than large-scale air conditioning units.
Moreover, water-cooling solutions can be integrated with external cooling towers or district cooling networks in some regions to reduce energy footprint.
Immersion Cooling
The system’s overhead is significantly decreased without fans constantly moving air. Two-phase immersion systems can be incredibly efficient since the phase change process is highly effective at transporting heat.
This can lead to smaller, more straightforward facility cooling infrastructures and lower operating costs.
Water Usage
Water is one of the most common liquids used in cooling systems, but its consumption can be a significant environmental consideration.
Conventional data centers consume large amounts of water for air conditioning and evaporative cooling. With direct water cooling, the water typically runs in a closed loop, mitigating overall usage.
On the other hand, immersion cooling systems often use synthetic dielectric fluids rather than water, which reduces strain on local water resources but introduces other environmental considerations in producing and disposing of these fluids.
Heat Reuse
An intriguing benefit of both liquid and immersion cooling systems is the potential for heat reuse. The heated fluid or vapor can be captured and transferred to other facilities that need heat or hot water, effectively recycling the thermal energy and reducing the total carbon footprint.
This holistic view of energy management transforms wasted heat into a resource, making data centers more sustainable overall.
The Future of Cooling
As data centers continue to proliferate globally and computing needs climb steadily, the evolution of cooling technologies will remain central to driving higher efficiencies.
More powerful chips will drive heat output even higher, and the quest to handle this heat with minimal energy input will spur innovation.
- Next-Generation Fluids: Research continues into more advanced dielectric fluids with even better thermal properties, reduced environmental impact, and lower cost.
- Hybrid Approaches: Some facilities may adopt hybrid solutions: immersion cooling for the most heat-intensive racks and conventional liquid cooling for others.
- AI-Driven Controls: As AI and data analytics improve, cooling systems might be dynamically managed to optimize fluid flow rates, temperature setpoints, and phase transitions in real time.
- Regulatory and Policy Pressures: Governments and environmental organizations increasingly scrutinize data center energy usage and resource consumption. This pressure encourages sustainable and efficient cooling methods, potentially driving further immersion and advanced liquid cooling adoption.
Learn More About Liquid Cooling vs Immersion Cooling
Liquid and immersion cooling use fluids to effectively remove heat from data center hardware, offering superior performance and efficiency compared to traditional air-based methods.
Liquid cooling suits incremental upgrades with lower initial risk, while immersion cooling excels in extreme environments needing uniform heat removal. Though immersion’s initial costs can be higher, it may yield significant long-term savings.
Whichever solution you choose, advanced cooling is essential for sustained high performance and reduced power usage in today’s data-centric world.